SUBSEA QUALIFIED SERIAL / 4-20 mA / CAN BUS GATEWAY

The Model 922-QSS is a subsea qualified SIIS Level 1, 2 and IWIS gateway enabling sensors, valves and other I/O to communicate with a modern SIIS level 3 control system. A single model 922-QSS supports multiple serial, fault tolerant CAN Bus and 4-20 mA channels reducing card count and architecture complexity.

Each serial channel is completely independent, providing maximum fault tolerance. The fault tolerant CAN Bus and 4-20 mA are on a separate expansion card, and provide high channel isolation, and protection features.

Real time advanced diagnostics are provided via standard Modbus TCP available over any of the Ethernet connections.

Compatible with other 922 products (e.g. 922-MES) and provides a unified software interface to simplify integration.

Features

  • 4 serial channels supporting RS-232 / 422 / 485, software configurable
  • Serial-UDP, Modbus RTU – Modbus TCP, PPP-IP
  • Option for 4 x SIIS level 2 (CAN Bus per ISO 11893-3, Fault Tolerant) and 20 x SIIS level 1 (4-20 mA) with expansion card
  • Isolation, reverse polarity protection, over-voltage protection
  • 3 port SIIS level 3 switch
  • DHCP-configured IP address with static IP backup
  • Qualified per ISO 13628-6 / API 17F
  • MTBF > 200,000 hours at +40°C
  • Advanced diagnostics and configuration using Modbus TCP
  • 3U Eurocard form-factor with options for front panel
  • Failsafe remote firmware update

Benefits

  • Proven SIIS level I, II, III and IWIS solution for subsea communications
  • Reduces cost by using standard configurations
  • Reduces card count and architecture complexity by supporting multiple I/O
  • Simplifies integration with unified software interface

Typical Applications

  • Subsea communications
  • Subsea drilling and production
  • Subsea Electronics Modules (SEM) and other subsea distribution nodes
  • Upgrades available for legacy communication systems

Specifications

Ìý

ÌýModel 922-QSS Specifications
SIIS Level 2 (Serial RS-232 / 422 IWIS / 485)

No. Ports

4 (4 on 96-pin DIN)
Format RS-232 / 422 / 485, software configurable
Baud Rate 230.4 kbaud max.
Protection Includes broadcast storm protection, rate limiting, flow control, 802.1q VLAN, 802.1p port priority, port mirroring, fast aging
Isolation 1000 Vrms
SIIS Level 1 (4-20 mA)
No. Channels 20 (20 on Expansion Card 96-pin DIN)
Sampling 1 ms
Resolution ± 0.25% F.S.
Protection Over-voltage up to ±25V; ESD ±15 kV air,
±8 kV contact
Isolation 1000 Vrms
SIIS Level 2 (Fault Tolerant CAN Bus) *
No. Channels Bidirectional (single fiber) transceivers
Format CAN Bus, Fault tolerant according to ISO 11898-3,
11 bit identifier field
Baud Rate 50 / 125 kbps (default 50 kbps)
Protocol CANopen
Protection Over-voltage up to ±25V; ESD ±15 kV air, ±8 kV contact
Isolation 1000 Vrms
SIIS Level 3 (Ethernet)
No. Ports Copper : 3 (2 on 96-pin DIN, 1 on Front)
Format SIIS level 3, 10/100 Base-T(X)
Rated Current 0.4 A max.
Protection ESD, EMI, over-voltage, reverse voltage, overcurrent (no fuses), 500 Vrms isolation
Connectors
Backplane 1 x 96-pin DIN 416612
Front 1 x 9-pin Micro-D
Expansion TBD
Option Additional 96-pin DIN with Expansion Card
Power
Consumption SIIS-Medium, 5.5 W typical (6 W max.)
Voltage +20 to +28 VDC, regulated
Current 0.2A (0.5 A max.)
Protection ESD, EMI, over-voltage, reverse voltage, overcurrent (no fuses)
Management
Operating Modes Serial - Ethernet Gateway, CAN - Ethernet Gateway, IWIS PPP– IP gateway, MODBUS RTU - TCP Gateway
Ethernet Switch Layer 2, Broadcast storm protection, rate limiting, flow control, 802.1q VLAN, DHCP, 802.1p port Priority, port mirroring
Diagnostics and Configuration LED, Webserver, Modbus TCP / RTU, CLI, TELNET
Firmware Update Fail safe remote firmware update
Mechanical
Dimensions
3U Eurocard, 160 mm x 100 mm x 4 HP
Mounting
Eurocard 3U rack or 4 x M3 hardware
Options
Front panel, Expansion Card for CAN Bus and
4-20 mA
Life Cycle
Design Life
> 20 years @ +40°C
MTBF
> 200,000 hrs @ +40°C
Testing
Factory Acceptance Test (FAT) at min. and max. temperature
Options
Environmental Stress Screening, thermal or vibration
Environmental
Temperature
-20°C to +70°C (operation)
-40°C to +85°C (storage)
Humidity
5% to 85% RH, non-condensing
Vibration
5 g, per ISO13628-6 / API 17F
Shock
30 g, per ISO 13628-6 / API 17F
Qualification
ISO 13628-6 Q1 / API 17F
Options
8000 PSI rated

*Option with CAN420 expansion card

Resources