Áõ«hÊ״δóÕ½ºÚÈË

Pressure Management Assembly (PMA)


The Pressure Management Assembly (PMA) is a single fault tolerant, parallel redundant branch regulation assembly that stabilizes and controls xenon inlet pressure to a downstream, low pressure flow control device. Regulation is mechanical with no electrical input required for operation. Flow isolation is provided by latch valves, and initially with normally closed pyro valves. High and low pressure transducers are incorporated for telemetry feedback. The complete welded assembly is incorporated on a flight plate with component brackets.

Ìý

Ìý

CONTACT OUR EXPERTS >

Ìý

Parameter Performance
Materials of Construction CRES 316L at tube interfaces
Pressure Range 0–6.9 bar low (0–100 psia), 0–186 bar high (0–2700 psia)
MEOP / Proof / Burst PressureÌý 6-186 / 279 / 558 bar, inlet (88-2700 / 4050 / 8100 psia)
External LeakageÌý < 1.0 x 10-6 sccs GHe at MEOPÌý
Supply Voltage 28 Vdc nominal
Regulated Pressure 2.55 ± 0.1 bar (37.0 ± 1.45 psia)
Regulator Lock Up Pressure 3.45 bar max (50 psia max)
Flow Rate 4 – 60 mg/s Xenon over pressure range
Regulator Internal Leakage < 3 scc/hr Xenon over pressure range
Latch Valve Internal Leakage 8.4 x 10-4 scc/sec GHe over pressure range (both valves)
Latch Valve Actuation Voltage 26.5 – 41.5 Vdc
Latch Valve Coil Resistance 58 ± 1 ohms at 20°C
Latch Valve Insulation Resistance > 1 Mohm at 100Vdc, 60 sec, all leads to body
Latch Valve Dielectric Strength < 100 mA at 500Vac, 60 sec, all leads to body
Latch Valve Response < 50 ms at MEOP
Latch Valve Inlet Filtration 5 micron abs (capacity of 83mg SAE fine dust at 25 psid)
Transducer Output (Signal) Voltage 0 to 5 VdcÌý
Transducer Total Error Band ± 2.25% FS over the temperature range
Transducer Insulation Resistance > 100 Mohm at 100Vdc, 30 sec, all leads to body
Transducer Dielectric Resistance 1.0 mA max at 50 Vac RMS and 60 Hz
Transducer Connector MS3116-10-6S
Sinusoidal Vibration 5 – 100 Hz, 13g peak
Random Vibration 14.9 grms overall – see included PSD plot below
Shock 3 axis, 100Hz/400g, 1000Hz/1400g, 10kHz/10000g (input levels) (isolated with Áõ«hÊ״δóÕ½ºÚÈËManufactured shock isolators)
Thermal Cycle

-33 to 71°C (-27 to 160°F) non-operational (4 cycles)

17 to 60°C (62.6 to 140°F) operational (6 cycles thermal, 4 cycles thermal vacuum)

Cycle Life > 12,000
Overall Envelope 188W x 476L x 91H (mm)
Mass 3750 g max with Áõ«hÊ״δóÕ½ºÚÈËsupplied shock isolators (not shown
Heritage More than 40 geosynchronous orbit to date

Ìý