Pressure Regulation Assembly (PRA)
Jump To:
Features
Literature
Related Áõ«hÊ״δóÕ½ºÚÈË
Ìý
Characteristic | Performance / Interfaces |
Materials of Construction | Stainless Steel, Aluminum flight plate |
MEOP / Proof / Burst | 2700 / 4050 / 6750 psia (186 / 279 / 465 bar) |
Regulated Pressure | 37 psia (2.55 bar) typical, any range from 0 – inlet pressure possible |
External Leakage | < 1e-6 scc/s, GHe @ MEOP |
Supply Voltage | 28 Vdc, Ìý6-11 Vdc equivalent PFCV operating range (current driven) Ìý |
Internal Leakage | < 8.3e-4 scc/s GHe @ MEOP per valve |
Minimum Flow Rate Capacity | 23 mg/sec GXe maximum at 37 psia inletÌýÌý |
FluidsÌý | GXe, GAr, GHe, GN2 |
Temperature Range(s) | Operating: -10 to 60°C (14 to 140°F) Non-operating: -35 to 70°C (-31 to 158°F) |
Transducer Voltage | 10Vdc nominal supply, 0-25 mVdc HP, 0-8 mVdc LP output |
Filtration | 25 micron absolute per each PFCV |
Sine Vibration | Up to 13g |
Random Vibration | 14.1 grms |
Shock | Up to 2000g @ 2000 HzÌý |
Mass | < 3 lbm (1.4 kg) |
Heritage | D2S2 |